DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS  
DIRECTOR’S OFFICE  
GENERAL INDUSTRY SAFETY AND HEALTH STANDARD  
(By authority conferred on the director of the department of licensing and regulatory affairs  
by sections 16 and 21 of the Michigan occupational safety and health act, 1974 PA 154,  
MCL 408.1016 and 408.1021, and Executive Reorganization Order Nos. 1996-2, 2003-1,  
2008-4, and 2011-4, MCL 445.2001, 445.2011, 445.2025, and 445.2030)  
PART 7. GUARDS FOR POWER TRANSMISSION  
R 408.10701 Scope.  
Rule 701. This part applies to all equipment used in the transmission of power, excluding  
the point of operation.  
History: 1979 AC.  
R 408.10702 Referenced standard.  
Rule 702. The Michigan Occupational Safety and Health Administration (MIOSHA)  
standard General Industry Safety and Health Standard Part 2. “Walking-Working  
Surfaces,” R 408.10201 to R 408.10241, is referenced in these rules. Up to 5 copies of this  
standard may be obtained at no charge from the Michigan Department of Licensing and  
Regulatory Affairs, MIOSHA Regulatory Services Section, 530 West Allegan Street, P.O.  
Box 30643, Lansing, Michigan, 48909-8143 or via the internet at the following website:  
www.michigan.gov/mioshastandards. For quantities greater than 5, the cost, at the time of  
adoption of these rules, is 4 cents per page.  
History: 2016 AACS; 2019 AACS.  
R 408.10703 Definitions; B to G.  
Rule 703. (1) "Belt" includes any power transmission belt, including, but not limited to,  
a flat belt, round belt, and V-belt, overhead chain and link belt. It does not include a  
conveyor belt.  
(2) "Belt pole" means a device used in shifting belts on and off fixed pulleys on a line or  
countershaft if there are no loose pulleys.  
(3) "Belt shifter" means a device for mechanically shifting belts from tight to loose idler  
pulleys or vice versa, or for shifting belts on cones of speed pulleys.  
(4) "Exposed to contact" means that the location of an object is such that a person might  
come into contact with it and be injured.  
Page 1  
(5) "Flywheel" includes a balance wheel and a flywheel pulley mounted and revolving on  
the crankshaft of an engine or other shafting.  
(6) "Gears" means a set or train of wheels or parts that engages another part as by meshing  
teeth.  
(7) "Guarded" or "enclosed" means that an object is covered, fenced, or surrounded so  
that it is not exposed to contact.  
History: 1979 AC; 1982 AACS.  
R 408.10704 Definitions; H to V.  
Rule 704. (1) "Horizontal belt" means a belt running within a 60 degree angle from  
horizontal.  
(2) "Maintenance runway" means a permanent runway or platform used for oiling,  
maintenance, running adjustment, or repair work, but not for a passageway.  
(3) "Nip-point belt and pulley guard" means a device which encloses a pulley and is  
provided with rounded or rolled edge slots through which the belt passes.  
(4) "Point of operation" means that point at which cutting, shaping, or forming by a  
machine is accomplished upon stock and other points that may offer a hazard to the  
operator in inserting or manipulating stock in the operation of the machine.  
(5) "Securely fastened" means that the safety device or object referred to shall be so  
secured in place that it cannot be moved under normal or reasonably foreseen conditions  
or circumstances.  
(6) "Vertical belt" means a belt running within a 30 degree angle from vertical.  
History: 1979 AC.  
POWER TRANSMISSION EQUIPMENT  
R 408.10711 Flywheels.  
Rule 711. An employer shall ensure that any part of a flywheel 7 feet or less above the  
floor or platform is guarded in 1 of the following ways:  
(a) Enclosed by a guard pursuant to R 408.10751 to R 408.10754.  
(b) With guardrail systems placed not less than 15, nor more than 20, inches from the rim  
of the flywheel in compliance with General Industry Safety and Health Standard Part 2.  
“Walking-Working Surfaces,” as referenced in R 408.10702.  
(c) The upper rim of a flywheel protruding through a working floor is enclosed or  
surrounded by a guardrail system in compliance with General Industry Safety and Health  
Standard Part 2. “Walking-Working Surfaces,” as referenced in R 408.10702.  
(d) A flywheel with a smooth rim 5 feet or less in diameter may be guarded pursuant to  
R 408.10756.  
History: 1979 AC; 1982 AACS; 2016 AACS; 2019 AACS.  
Page 2  
R 408.10712 Cranks and connecting rods.  
Rule 712. A crank and a connecting rod, if exposed to contact, must be guarded pursuant  
to R 408.10751 to R 408.10754 or by a guardrail system in compliance with General  
Industry Safety and Health Standard Part 2. “Walking-Working Surfaces,” as referenced  
in R 408.10702.  
History: 1979 AC; 1982 AACS; 2016 AACS; 2019 AACS.  
R 408.10713 Tail rods and extension piston rods.  
Rule 713. Tail rods and extension piston rods exposed to contact must be guarded  
pursuant to R 408.10751 to R 408.10754 or by a guardrail system in compliance with  
General Industry Safety and Health Standard Part 2. “Walking-Working Surfaces,” as  
referenced in R 408.10702, which allows a clearance of not less than 15, nor more than 20,  
inches from the fully extended tail rod or extension piston rod.  
History: 1979 AC; 1982 AACS; 2016 AACS; 2019 AACS.  
R 408.10714 Rescinded.  
History: 1979 AC; 1982 AACS.  
R 408.10715 Discharge or exhaust pipes.  
Rule 715. The discharge of an exhaust pipe or boiler blowoff, if exposed to contact, shall  
be guarded pursuant to R 408.10751 to R 408.10754.  
History: 1979 AC; 1982 AACS.  
R 408.10716 Revolving and reciprocating parts.  
Rule 716. A revolving or reciprocating part, if exposed to contact, shall be guarded  
pursuant to R 408.10751 to R 408.10754.  
History: 1979 AC; 1982 AACS.  
R 408.10721 Shafts.  
Rule 721. (1) A continuous line of shafting shall be secured in position against endwise  
movement.  
(2) An inclined or vertical shaft will be held in position against endwise trust.  
(3) A project shaft end, if exposed to contact, shall be made flush or guarded pursuant to  
R 408.10751 to R 408.10754.  
History: 1979 AC; 1982 AACS.  
Page 3  
R 408.10722 Shafting.  
Rule 722. (1) Shafting exposed to contact 7 feet or less above a floor or platform level  
shall be guarded pursuant to R 408.10751 to R 408.10754.  
(2) Horizontal shafting extending over a driveway shall be guarded with a trough guard  
unless it is located 15 feet or more above the driveway or is a part of an overhead traveling  
crane.  
(3) Horizontal transmission shafting exposed to contact under benches shall be guarded  
in 1 of the following ways:  
(a) Be completely enclosed.  
(b) Be guarded by a trough guard. The sides of the trough shall come to the underside of  
the table or, if the shafting is located near a floor, to the floor.  
(c) Be guarded on exposed sides with a rigid shield guard extending from the underside  
of the bench top to 2 inches below the line of shafting.  
History: 1979 AC; 1982 AACS.  
R 408.10723 Rescinded.  
History: 1979 AC.  
R 408.10725 Pulley guards and guides.  
Rule 725. (1) A pulley and a pulley part exposed to contact 7 feet or less from the floor  
or platform shall be guarded pursuant to R 408.10751 to R 408.10754.  
(2) If the distance from a pulley to the nearest fixed pulley, clutch, or hanger is less than  
the width of the belt used, a guide shall be provided to prevent the belt from leaving the  
pulley.  
(3) If there is an overhanging pulley on a line, jack, or countershaft with no bearing  
between the pulley and the outer end of the shaft, a guide to prevent the belt from running  
off the pulley shall be provided.  
History: 1979 AC; 1982 AACS.  
R 408.10726 Pulley condition and operation.  
Rule 726. (1) A pulley with a defect, including, but not limited to, a crack or a piece  
broken out, shall not be used.  
(2) A pulley subject to active corrosive conditions shall be of corrosion-resisting material.  
(3) A pulley permanently out of service shall not be allowed to remain on shafting which  
is in use, unless enclosed with a guard pursuant to R 408.10751 to R 408.10754.  
(4) A pulley shall not be operated at more than its designed rim speed.  
History: 1979 AC; 1982 AACS.  
Page 4  
R 408.10727 Belts.  
Rule 727. (1) A belt and pulley that is 7 feet or less above the floor or platform and that  
is exposed to contact must be guarded pursuant to R 408.10751 to R 408.10754. In a power  
plant or power-development room, a guardrail system may be used in compliance with  
General Industry Safety and Health Standard Part 2. “Walking-Working Surfaces,” as  
referenced in R 408.10702.  
(2) A horizontal belt more than 7 feet above the floor or platform must be guarded for its  
entire length if located over a passageway or work place pursuant to R 408.10753 and  
figure 2 contained in subrule (5) of this rule.  
(3) A passageway between horizontal belts must have a lower run guarded by a platform  
that is provided with a guardrail system in compliance with General Industry Safety and  
Health Standard Part 2. “Walking-Working Surfaces,” as referenced in R 408.10702, and  
the upper run guarded pursuant to subrule (2) of this rule.  
(4) A vertical or inclined belt running over a lower pulley more than 7 feet above the floor  
or platform and located over a passageway or work place must be guarded pursuant to  
subrule (2) of this rule.  
(5) Figure 2 reads as follows:  
FIGURE 2  
Page 5  
History: 1979 AC; 1982 AACS; 2016 AACS; 2019 AACS.  
R 408.10728 Rescinded.  
Page 6  
History: 1979 AC.  
R 408.10729 Cone pulley belts.  
Rule 729. (1) A cone belt and pulley shall be equipped with a belt shifter so constructed  
as to adequately guard the nip-point of the belt and pulley. If the frame of the belt shifter  
does not adequately guard the nip-point of the belt and pulley, the nip-point shall be further  
protected by means of a guard which extends at least to the top of the largest step of the  
cone.  
(2) If the belt is of the endless type or laced with rawhide laces, and a belt shifter is not  
desired, the belt will be considered guarded if the nip-point of the belt and pulley is  
protected by a nip-point guard which extends at least to the top of the largest step of the  
cone, and formed to show the contour of the cone in order to give the nip-point of the belt  
and pulley the maximum protection.  
(3) If the cone is located less than 3 feet from the floor or working platform, the cone  
pulley and belt shall be guarded to a height of 3 feet regardless of whether the belt is endless  
or laced with rawhide.  
History: 1979 AC.  
R 408.10730 Belt tighteners and counterweights.  
Rule 730. (1) A suspended counterbalanced belt tightener and its parts shall be provided  
with a safety cable or device to prevent the tightener from being exposed to contact if the  
belt breaks or they shall be guarded pursuant to R 408.10751 to R 408.10754.  
(2) A suspended counterweight exposed to contact or a part of a counterweight which  
could subject an employee to injury shall be guarded pursuant to R 408.10751 to R  
408.10754 or shall be provided with a safety cable or device to prevent a fall.  
History: 1979 AC; 1982 AACS.  
R 408.10731 Gears, sprockets, and chain drives.  
Rule 731. (1) Gears, sprockets, and chain drives exposed to contact shall be guarded  
pursuant to R 408.10751 to R 408.10754. This does not apply to hand-operated gear  
sprockets and chain drives used to adjust machine parts which do not move after hand  
power is removed.  
(2) Protection against falling chain or metal belts shall be provided pursuant to R  
408.10751 to R 408.10754 where drives extend over a work area or passageway.  
History: 1979 AC; 1982 AACS.  
R 408.10732 Openings for oiling.  
Rule 732. If frequent oiling is necessary, openings with hinged or sliding self-closing  
covers shall be provided. Points not readily accessible shall have remote lubricating means  
Page 7  
if the lubricant is to be added while machinery is in motion and the oiler would be exposed  
to contact.  
History: 1979 AC.  
R 408.10734 Friction drives.  
Rule 734. The driving points and moving parts of friction drives, if exposed to contact,  
shall be guarded pursuant to R 408.10751 to R 408.10754.  
History: 1979 AC; 1982 AACS.  
R 408.10736 Projections.  
Rule 736. Projecting keys, set screws, and other projections in revolving parts exposed to  
contact shall be removed, made flush, or guarded. This does not apply to keys or set screws  
within gear or sprocket casings or other enclosures, nor to keys, set screws, or oil cups in  
hubs of pulleys less than 20 inches in diameter if they are within the plane of the rim of the  
pulley.  
History: 1979 AC.  
R 408.10738 Rescinded.  
History: 1979 AC.  
STARTING AND STOPPING DEVICES  
R 408.10741 Clutches.  
Rule 741. (1) A clutch, cut-off coupling, or clutch pulley having any projecting parts  
exposed to contact shall be enclosed by a stationary guard constructed pursuant to R  
408.10751 to R 408.10754.  
(2) On a line shaft the shifting part of a jaw clutch and the shifting or mechanism part of  
a friction clutch coupling shall be attached to the driven shaft.  
History: 1979 AC; 1982 AACS.  
R 408.10743 Belt shifters.  
Rule 743. (1) A tight pulley and a loose pulley shall be equipped with a permanent belt  
shifter provided with mechanical means to prevent the belt from creeping from the loose  
to the tight pulley.  
(2) A belt shifter and clutch handle shall be rounded and be located to prevent being  
exposed to contact, but within easy reach of the operator. If an overhead belt shifter is not  
Page 8  
directly located over a machine or bench, the handles shall be cut off 7 feet above floor  
level.  
History: 1979 AC.  
R 408.10744 Belt poles, perches, and fasteners.  
Rule 744. (1) If loose pulleys or idlers are not practicable, belt perches in the form of  
brackets and rollers shall be used to keep idle belts away from the shafts.  
(2) Belts shifted by hand shall be glued or fastened with leather lacing.  
History: 1979 AC; 1982 AACS.  
GUARD DESIGN AND CONSTRUCTION  
R 408.10751 Design.  
Rule 751. (1) The design of a guard shall take into consideration:  
(a) The nature of protection required of the guard.  
(b) The possibility of guard failure.  
(c) The amount of maintenance required on the guard.  
(2) In a place where it is necessary to change belts, make adjustments, or apply oil or  
grease, a guard may have hinged sections or be of a removable design. A guard shall be  
closed or replaced after servicing.  
History: 1979 AC.  
R 408.10752 Construction.  
Rule 752. A guard shall be practicable, durable, and effective, and it shall not introduce a  
new hazard, including, but not limited to, burrs and sharp edges.  
History: 1979 AC.  
R 408.10753 Materials.  
Rule 753. (1) Wood guards may be used if the presence of fumes or if manufacturing  
conditions cause rapid deterioration of metal guards, in construction work, and in locations  
outdoors if extreme cold or extreme heat makes metal guards and railings undesirable.  
(2) Material sizes and clearances shall be pursuant to table A. See Figure 2, and  
Appendices A and B.  
(3) Table A reads as follows:  
Page 9  
TABLE A  
STANDARD MATERIALS AND DIMENSIONS FOR MACHINERY GUARDS  
Size and Clearance of Filler Materials  
Largest Mesh or  
Clearance  
From  
Minimum  
(U.S. Standard)  
Or Thickness  
Gauge  
Opening  
Allowable  
(Inches)  
Material  
Moving Part At All  
Points (Inches)  
B
Under 2  
2-4  
4-15  
3/8  
1/2  
2
No. 16-1/8 In.  
No. 16-1/2  
No. 12-2  
Woven Wire  
Under 4  
4-15  
1/2  
2
No. 18-1/2 In.  
No. 13-2  
Expanded Metal  
Perforated Metal  
Sheet Metal  
Under 4  
4-15  
1/2  
2
No. 20-1/2 In.  
No. 14-2  
Under 4  
4-15  
No. 22  
No. 22  
- - -  
Wood Or  
Metal  
Strips Crossed  
Under 4  
4-15  
1/2  
2
}
3/4  
Wood  
No.  
Metal  
In.  
Or  
16  
}
Wood Or  
Metal Strips  
Not Crossed  
Under 4  
4-15  
1/2 The Width  
One Width  
}
Plywood,  
Plastic  
Equivalent  
Under 4  
4-15  
1/4 In.  
1/4 In.  
Or  
- - -  
- - -  
Min. 15  
Max. 20  
Standard Railing  
- - -  
History: 1979 AC; 1982 AACS; 2016 AACS.  
R 408.10754 Frames.  
Rule 754. (1) If a guard has a frame, the material shall be securely fastened to it.  
(2) The minimum dimensions of materials in the frame of a guard shall be of sufficient  
strength and rigidity to hold the filler material fastened to it and to give the guard sufficient  
strength and rigidity in order to provide the desired protection.  
History: 1979 AC; 1982 AACS.  
Page 10  
R 408.10756 Disk guards.  
Rule 756. A disk guard shall be made of materials specified in table A of R 408.10753  
and fastened securely to spokes of pulleys, flywheels, or gears. If a possibility of contact  
with sharp edges of the disk exists, the edge shall be rolled. Lock nuts or washers shall be  
placed on the unexposed side of the wheel.  
History: 1979 AC; 1982 AACS.  
R 408.10757 Rescinded.  
History: 1979 AC; 1982 AACS.  
POWER DISCONNECTS AND LOCK-OUTS  
R 408.10761 Rescinded.  
History: 1979 AC; 2013 AACS.  
R 408.10763 Rescinded.  
History: 1979 AC; 1982 AACS; 2013 AACS.  
R 408.10765. Inspection and care of equipment; clothing for oilers.  
Rule 765. (1) All power-transmission equipment shall be inspected at intervals not  
exceeding 60 days and be kept in good working condition at all times.  
(2) Shafting shall be kept in alignment, free from rust and excess oil or grease.  
(3) Where explosives, explosive dusts, flammable vapors, or flammable liquids exist, the  
hazard of static sparks from shafting shall be carefully considered.  
(4) Bearings shall be kept in alignment and properly adjusted.  
(5) Hangers shall be inspected to make certain that all supporting bolts and screws are  
tight and that supports of hangers boxes are adjusted properly.  
(6) Pulleys shall be kept in proper alignment to prevent belts from running off.  
(7) Inspection shall be made of belts, lacings, and fasteners, and such equipment shall be  
kept in good repair.  
History: 1979 AC; 2013 AACS.  
Page 11  
;