(2) Work areas under mills shall be as evenly surfaced as local conditions permit. Work
areas under mills shall not have unnecessary obstructions and shall have lighting facilities
in accordance with ANSI A11.1 “Industrial Lighting” 1965 edition, as adopted in
R 408.15209
(3) Log dumps, booms, ponds, or storage areas used at night shall be illuminated in
accordance with the requirements of ANSI A11.1 “Industrial Lighting” 1965 edition, as
adopted in R 408.15209
(4) An employer shall ensure that illumination is provided and designed to supply
adequate general and local lighting to rooms, buildings, and work areas when in use.
(5) The adequacy and effectiveness of illumination shall be determined using all of the
following factors:
(a) The quantity of light in foot-candle intensity is sufficient for the work being done.
(b) The quality of the light is free from glare, and has correct direction, diffusion, and
distribution.
(c) Shadows and extreme contrasts are avoided or kept to a minimum.
(6) All stairways shall be adequately lighted as prescribed in subrules (4) and (5) of this
rule.
(7) Fuel houses, bunkers, hoppers, and bins shall have adequate exits and lighting, and
all necessary safety devices shall be provided. Persons entering fuel houses, bunkers,
hoppers, and bins shall use the safety devices.
History: 1979 AC; 2014 AACS.
R 408.15222 Walking-working surfaces.
Rule 5222. (1) An aisle or floor work area shall be kept free of protruding objects, holes,
and loose boards.
(2) A floor at the operator's station of a machine shall be maintained free of any slip or
trip hazard.
(3) A floor shall be capable of sustaining the imposed load.
(4) An aisle, passageway, roadway, or dock shall be of such width as to provide for the
safe passage of employees or vehicles, or both. A dock where powered industrial trucks
are used shall be provided with a guard or bumper along its perimeter, except at loading or
unloading points, to prevent overrun.
(5) A swinging door shall be provided with a window in each section. The window shall
be of clear safety glass or equivalent material or protected against breakage.
(6) Where a doorway opens upon a railroad track or upon a tramway or dock over which
vehicles travel, a barrier or other warning device shall be placed to prevent employees from
stepping into moving traffic.
(7) Where elevated platforms are used routinely on a daily basis, the elevated platforms
shall be equipped with stairways or fixed ladders that comply with General Industry Safety
and Health Standard Part 2 “Walking-Working Surfaces,” as referenced in R 408.15209.
(8) Stairways shall be constructed in accordance with General Industry Safety and Health
Standard Part 2 “Walking-Working Surfaces,” as referenced in R 408.15209.
(9) In dry kilns and facilities, a fixed ladder complying with the requirements General
Industry Safety and Health Standard Part 2 “Walking-Working Surfaces,” as referenced in
R 408.15209, or other adequate means, shall be provided to permit access to the roof.
Page 7