R 408.15723 Traveling blocks and crown blocks.
Rule 5723. (1) A traveling block and its component parts shall be designed, constructed,
and maintained as prescribed in API SPEC 8A-1976, entitled “Specifications for Drilling
and Production Hoisting Equipment,” which is adopted herein by reference and may be
inspected at the Department of Licensing and Regulatory Affairs, MIOSHA Standards
Section, 7150 Harris Drive, P.O. Box 30643, Lansing, Michigan, 48909-8143. The
specifications may be purchased at a cost of $125.00 from IHS Global, 15 Inverness Way
East, Englewood, Colorado, 80112, USA, telephone number: 1-800-854-7179 or via the
(2) A traveling block, crown block, or related equipment shall not be subjected to any
load in excess of its designed rating.
(3) A hook for use with a traveling block to which equipment is either directly or
indirectly attached shall be equipped with safety latch to prevent accidental release of the
load.
(4) A traveling block exposed to contact shall be guarded at the running nip point of the
sheave and shall not be operated unless the guard is in place.
History: 1979 AC; 1989 AACS; 2013 AACS.
R 408.15725 Electrical installations.
Rule 5725. (1) Except as required in this rule, electrical installations and equipment shall
be as prescribed in the national electrical code, NFPA 70-1981, which is adopted herein by
reference and may be inspected at the Department of Licensing and Regulatory Affairs,
MIOSHA Standards Section, 7150 Harris Drive, P.O. Box 30643, Lansing, Michigan,
48909-8143. This code may be purchased at the cost of $27.00 from the National Fire
Protection Association, Batterymarch Park, P.O. Box 9101, Quincy, Massachusetts 02269-
(2) Electrical equipment such as lighting, power tools, and other electrical motors used in
hazardous locations shall be designed for such locations and where practicable, listed by a
nationally recognized testing laboratory. All wiring components and electrical equipment
shall be maintained in accordance with the original design. Because of exposure to
vibration and frequent rig moves, maximum use shall be made of flexible electrical cord
intended for hard usage and with inherent resistance to dampness and petroleum products.
(3) On a land location, an engine-driven light plant or generator shall not be located closer
to the wellbore than the nearest engine operating the rig.
(4) A light plant generator shall have a overload safety device to provide protection from
arcing in a hazardous area or from a burnout of the generator.
(5) Rig lighting equipment, except that used in a cellar, shall be classified as class 1,
division 2.
(6) Cellar lighting equipment shall be classified class 1, division 1.
(7) The following area classifications shall determine the type of maintenance
requirements for electrical equipment on the rig under normal operating conditions. When
special service operations are being performed, the requirements for electrical installations
under the conditions of service listed in subdivisions (a) to (h) of this subrule shall be
followed: