DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS  
DIRECTOR’S OFFICE  
CONSTRUCTION CODE  
(By authority conferred on the director of the department of licensing and regulatory  
affairs by section 4 of the Stille-DeRossett-Hale single state construction code act, 1972  
PA 230, MCL 125.1504, and Executive Reorganization Order Nos. 2003-1, 2008-4, and  
2011-4, MCL 445.2011, 445.2025, and 445.2030)  
REHABILITATION CODE  
R 408.30551 Applicable code.  
Rule 551. The international existing building code, 2021 edition, including appendix A  
and resource A, referred to in these rules as "the code," is adopted by reference as the  
"Michigan rehabilitation code for existing buildings" with the exception of sections 103.1  
to 103.3, 104.8, 104.8.1, 104.10, 105.3 to 105.3.2, 108.2 to 108.6, 110.2, 110.3, 112.1 to  
112.4, 113.1 to 113.3, 114.1, 114.3 to 114.4, 705.1.1 to 705.2, 806.2, and Appendix B and  
C, and as otherwise noted in these rules. The international existing building code, 2021  
edition is available for inspection at the Michigan Department of Licensing and Regulatory  
Affairs, Bureau of Construction Codes, 611 West Ottawa Street, First Floor Ottawa  
Building, Lansing, Michigan 48933. The code may be purchased from the International  
Code Council, through the bureau’s website at www.michigan.gov/bcc, at a cost as of the  
time of adoption of these rules of $77.50.  
101.3 Purpose: The purpose of the code and the act is to provide the use of alternative  
approaches to achieve compliance with minimum requirements to provide a reasonable  
level of safety, health, property protection, and general welfare insofar as they are  
affected by the repair, alteration, change of occupancy, addition, and relocation of  
existing buildings. The act takes precedence over all provisions of the code.  
History: 2002 AACS; 2003 AACS; 2008 AACS; 2010 AACS; 2014 AACS; 2016 AACS; 2024 AACS.  
R 408.30552 References to international codes.  
Rule 552. All references to the code, national electrical code, international energy code,  
international building code, international residential code, international mechanical code,  
and international plumbing code in the international existing building code shall mean the  
Michigan building code, Michigan electrical code, Michigan uniform energy code,  
Michigan residential code, Michigan mechanical code and Michigan plumbing code,  
respectively.  
History: 2002 AACS; 2014 AACS.  
Page 1  
R 408.30553 Title.  
Rule 553. Section 101.1 of the code is amended as follows:  
101.1 Title. These rules shall be known as the Michigan rehabilitation code for existing  
buildings, hereinafter referred to as "this code."  
History: 2002 AACS.  
R 408.30554 Scope.  
Rule 554. Section 101.2 of the code is amended as follows:  
101.2 Scope. The provisions of this code shall apply to the repair, alteration, change of  
occupancy, addition, and relocation of existing buildings. A building or portion of a  
building which has not been previously occupied or used for its intended purpose shall  
comply with the provisions of the Michigan building code for new construction. Repairs,  
alterations, change of occupancy, existing buildings to which additions are made, historic  
buildings, and relocated buildings complying with the provisions of the Michigan building  
code, the Michigan electrical code, the Michigan residential code, the Michigan  
mechanical code, and the Michigan plumbing code shall be considered to be in compliance  
with this code.  
History: 2002 AACS.  
R 408.30555 Rescinded.  
History: 2002 AACS; 2003 AACS.  
R 408.30556 Rescinded.  
History: 2002 AACS; 2008 AACS; 2014 AACS; 2024 AACS.  
R 408.30557 Definitions.  
Rule 557. The definition of act and registered design professional in the act are added to  
section 202 of the code to read as follows:  
202. Definitions.  
(a) "Act" means the Stille-DeRossett-Hale single state construction code act, 1972 PA  
230, MCL 125.1501 to 125.1531.  
(b) "Registered design professional" means an individual who is licensed under the  
occupational code, 1980 PA 299, MCL 339.101 to 339.2677.  
History: 2002 AACS; 2008 AACS; 2010 AACS; 2024 AACS.  
R 408.30558 Preliminary meeting.  
Page 2  
Rule 558. Section 104.2.2 of the code is amended and 104.6 is added to read as follows:  
104.2.2. Preliminary meeting. When requested by the owner or owner’s agent, the  
building official shall meet with the owner or the owner’s agent to discuss plans for the  
proposed work or change of occupancy before the application for a construction permit in  
order to establish the specific applicability of the provisions of the code. The building  
official shall notify the appropriate fire official of the meeting.  
Exception: Repairs, and alterations level 1.  
104.6 Right of entry: If a building or premises are occupied, the code official shall  
present their credentials to the occupant and request entry. If a building or premises are  
unoccupied, the code official shall first make a reasonable effort to locate either the  
owner, the owner’s authorized agent, or another individual having care or control of the  
building or premises and request entry. If entry is refused, the code official has recourse  
to every remedy provided by law to secure entry. When a code official has first obtained  
a proper inspection warrant or other remedy provided by law to secure entry, the owner,  
the owner’s authorized agent, the occupant, or the individual having charge, care, or  
control of the building or premises shall not fail or neglect, after a proper request is made  
as provided in this rule, to allow the code official prompt entry into the building or  
premises to inspect or examine the building or premises pursuant to the code.  
History: 2002 AACS; 2003 AACS; 2016 AACS; 2024 AACS.  
R 408.30559 Rescinded.  
History: 2002 AACS; 2003 AACS; 2016 AACS; 2024 AACS.  
R 408.30560 Permits.  
Rule 560. Section 105.1 of the code is being added and 105.2 of the code is amended as  
follows:  
105.1 Required: Owners or their authorized agents shall obtain the required permit from  
a building official before undertaking any construction, enlargement, alteration, repair,  
relocation, demolition, change of occupancy, erection, installation, enlargement,  
alteration, repair, removal, conversion, or replacement of electrical, gas, mechanical,  
plumbing, or solar panel systems regulated by the code.  
105.2. Work exempt from permit. Exemptions from permit requirements of the code shall  
not grant authorization for work done in any manner in violation of the code or other laws  
or ordinances of this jurisdiction. Permits shall not be required for the following:  
(a) Building permits shall not be required for the following:  
(i) One-story detached accessory structures used as tool and storage sheds, playhouses,  
and similar uses, provided the floor area does not exceed 120 square feet, 11.15 square  
meters.  
(ii) A fence that is not more than 7 feet, 134 millimeters, high.  
(iii) Oil derricks.  
(iv) A retaining wall that is not more than 4 feet, 1,219 millimeters, in height measured  
from the bottom of the footing to the top of the wall, unless supporting a surcharge or  
impounding class I, II, or III-A liquids.  
Page 3  
(v) A water tank supported directly on grade if the capacity is not greater than 5,000  
gallons, 18 925 liters, and the ratio of height to diameter or width is not greater than 2 to 1.  
(vi) A sidewalk and driveway not more than 30 inches, 762 millimeters, above adjacent  
grade and not over any basement or story below and are not part of an accessible route.  
(vii) Painting, papering, tiling, carpeting, cabinets, countertops, and similar finish work.  
(viii) Temporary motion picture, television, and theater stage sets and scenery.  
(ix) Prefabricated swimming pools accessory to a group R-3 occupancy, as applicable in  
section 101.2, that are less than 24 inches, 610 millimeters, deep, are not greater than 5,000  
gallons, 18,925 liters, and are installed entirely above ground.  
(x) Shade cloth structures constructed for nursery or agricultural purposes and not  
including service systems.  
(xi) Swings and other playground equipment accessory to detached 1- and 2-family  
dwellings.  
(xii) Window awnings in group R-3 and U occupancies, supported by an exterior wall  
that do not project more than 54 inches, 1,372 millimeters, from the exterior wall and do  
not require additional support, as applicable in section 101.2.  
(xiii) Nonfixed and movable fixtures, cases, racks, counters, and partitions not over 5 feet  
9 inches, 1,753 millimeters, in height.  
(b) Electrical permits shall not be required, pursuant to R 408.30801 to R 408.30880, for  
the following:  
(i) Repairs and maintenance: Minor repair work, including the replacement of lamps or  
the connection of approved portable electrical equipment to approved permanently  
installed receptacles.  
(ii) Radio and television transmitting stations: The provisions of the code do not apply to  
electrical equipment used for radio and television transmissions, but they do apply to  
equipment and wiring for power supply and to the installation of towers and antennas.  
(iii) Temporary testing systems: A permit shall not be required for the installation of any  
temporary system required for the testing or servicing of electrical equipment or apparatus.  
(c) Mechanical permits shall not be required for the following:  
(i) A portable gas heating or gas appliance that has inputs of less than 30,000 Btu’s per  
hour.  
(ii) Portable ventilation appliances and equipment.  
(iii) A portable cooling unit.  
(iv) Steam, hot water, or chilled water piping within heating or cooling equipment or  
appliances regulated by the code.  
(v) Replacement of a minor part that does not alter the approval of equipment or an  
appliance or make the equipment or appliance unsafe.  
(vi) A portable evaporative cooler.  
(vii) Self-contained refrigeration systems that contain 10 pounds, 4.5 kilograms, or less  
of refrigerant, or that are actuated by motors of 1 horsepower, 0.75 kilowatts, or less.  
(viii) Portable fuel cell appliances that are not connected to a fixed piping system and are  
not interconnected to a power grid.  
(ix) An oil burner that does not require connection to a flue, such as an oil stove and a  
heater equipped with a wick.  
(x) A portable gas burner that has inputs of less than 30,000 Btu’s per hour.  
Page 4  
(xi) When changing or relocating a gas meter or regulator, a permit is not required when  
installing gas piping which shall be limited to 10 feet, 3,005 millimeters, in length and not  
more than 6 fittings.  
(xii) When installing geothermal vertical closed loops under the supervision of a  
mechanical contractor licensed in heating, ventilation and air conditioning, “HVAC”, as  
long as the company meets both of the following:  
(A) Has obtained a certificate of registration as a well drilling contractor pursuant to part  
127 of the public health code, 1978 PA 368, MCL 333.12701 to 333.12771.  
(B) Has installed the geothermal vertical closed loops pursuant to the department  
of environment, Great Lakes, and energy best practices regarding geothermal heat pump  
closed loops.  
Exemption from the permit requirements of the code shall not be deemed to grant  
authorization for work done in violation of the provisions of the code or other laws or  
ordinances of this jurisdiction.  
(d) Plumbing permits shall not be required for either of the following:  
(i) The stopping of leaks in drains, water, soil, waste, or vent pipe. However, if any  
concealed trap, drainpipe, water, soil, waste, or vent pipe becomes defective and it becomes  
necessary to remove and replace the drain or pipe with new material, the work is considered  
new work and a permit shall be obtained and inspection made as provided in the code.  
(ii) The clearing of stoppages or the repairing of leaks in pipes, valves, or fixtures, and  
the removal and reinstallation of water closets, if the repairs do not involve or require the  
replacement or rearrangement of valves, pipes, or fixtures.  
History: 2002 AACS; 2003 AACS; 2010 AACS; 2014 AACS; 2024 AACS.  
Editor's Note: An obvious error in R 408.30560 was corrected at the request of the promulgating agency,  
pursuant to Section 56 of 1969 PA 306, as amended by 2000 PA 262, MCL 24.256. The rule containing the  
error was published in Michigan Register, 2024 MR 23. The memorandum requesting the correction was  
published in Michigan Register, 2025 MR 20.  
R 408.30561 Accessibility.  
Rule 561. Sections 306.1, 306.7, 306.7.1, 306.7.7, and 306.7.8 of the code are amended  
as follows:  
306.1. Scope. A building, facility, or element that has a change in use group or occupancy  
load or alteration shall comply with the requirements of 1966 PA 1, MCL 125.1351 to  
125.1356, and R 408.30401 to R 408.30499a.  
306.7. Alterations. A building, facility, or element that is altered shall comply with the  
applicable provisions in chapter 11 of the Michigan building code and ICC/A117.1 listed  
in chapter 16, of the Michigan building code unless technically infeasible. When  
compliance with this section is technically infeasible, the alteration shall provide access to  
the maximum extent technically feasible.  
Exceptions:  
(1) The altered element or space is not required to be on an accessible route, unless  
required by section 306.7.1 of the code.  
(2) Accessible means of egress required by chapter 10 of the Michigan building code are  
not required to be provided in existing buildings and facilities.  
Page 5  
(3) Buildings, structures, or improved areas that exist on or before the effective date of  
these rules and comply with the code at the time of the issuance of the certificate of  
occupancy unless the alteration specifically modifies an area covered by sections 306.7 to  
306.7.7 of the code.  
(4) The alteration to type A individually owned dwelling units within a group R-2  
occupancy shall meet the provisions for a type B dwelling unit and shall comply with the  
applicable provisions in chapter 11 of the Michigan building code and ICC/A 117.1 listed  
in chapter 16 of the Michigan building code.  
306.7.1 Alterations affecting an area containing a primary function. Where an alteration  
affects the accessibility to, or contains an area of, primary function, the route to the primary  
function area shall be accessible. The accessible route to the primary function area shall  
include toilet facilities and drinking fountains serving the area of primary function.  
Exceptions:  
(a) This provision does not apply to alterations limited solely to windows, hardware,  
operating controls, electrical outlets, and signs.  
(b) This provision does not apply to alterations limited solely to mechanical systems,  
electrical systems, installation or alteration of fire protection systems, and abatement of  
hazardous materials.  
(c) This provision does not apply to alterations undertaken for the primary purpose of  
increasing the accessibility of an existing building, facility, or element.  
(d) This provision does not apply to altered areas limited to type B dwelling and sleeping  
units.  
306.7.7. Elevators. Altered elements of existing elevators shall comply with the Michigan  
elevator code, R 408.7001 to R 408.8695. These elements shall also be altered in elevators  
programmed to respond to the same hall call control as the altered elevator.  
306.7.8. Platform lifts. Platform or wheelchair lifts complying with ICC/A 117.1 listed  
in chapter 16 of the Michigan building code, and installed in accordance with the Michigan  
elevator code, R 408.7001 to R 408.8695 shall be allowed as a component of an accessible  
route.  
History: 2002 AACS; 2008 AACS; 2010 AACS; 2014 AACS; 2016 AACS; 2024 AACS.  
R 408.30562 Rescinded.  
History: 2002 AACS; 2008 AACS; 2024 AACS.  
R 408.30563 Rescinded.  
History: 2002 AACS; 2003 AACS; 2014 AACS; 2016 AACS.  
R 408.30564 Elevator control.  
Rule 564. Section 1301.6.14 of the code is amended as follows:  
1301.6.14. Elevator control. Evaluate the passenger elevator equipment and controls that  
are available to the fire department to reach all occupied floors. Elevator recall controls  
Page 6  
shall be provided pursuant to the Michigan elevator code, R 408.7001 to R 408.8695.  
Under the categories and occupancies in table 1301.6.14, determine the appropriate value  
and enter that value into table 1401.7 under safety parameter 1301.6.14, elevator control,  
for fire safety, means of egress, and general safety. The values shall be zero for a single-  
story building.  
History: 2002 AACS; 2008 AACS; 2014 AACS; 2024 AACS.  
Editor's Note: An obvious error in R 408.30564 was corrected at the request of the promulgating agency,  
pursuant to Section 56 of 1969 PA 306, as amended by 2000 PA 262, MCL 24.256. The rule containing the  
error was published in Michigan Register, 2024 MR 23. The memorandum requesting the correction was  
published in Michigan Register, 2025 MR 20.  
R 408.30565 Rescinded.  
History: 2002 AACS; 2008 AACS; 2024 AACS.  
R 408.30565a Rescinded.  
History: 2014 AACS; 2016 AACS; 2024 AACS.  
R 408.30566 Rescinded.  
History: 2002 AACS; 2003 AACS; 2005 AACS; 2008 AACS; 2014 AACS; 2016 AACS; 2024 AACS.  
R 408.30567 Rescinded.  
History: 2002 AACS; 2003 AACS.  
R 408.30568 Rescinded.  
History: 2002 AACS; 2008 AACS; 2014 AACS; 2024 AACS.  
R 408.30569 Rescinded.  
History: 2002 AACS; 2008 AACS; 2010 AACS; 2014 AACS; 2016 AACS.  
R 408.30570 Rescinded.  
History: 2002 AACS; 2008 AACS; 2010 AACS; 2014 AACS; 2024 AACS.  
Page 7  
R 408.30571 Violation penalties.  
Rule 571. Section 109.6 is added and section 113.4 of the code is amended as follows:  
109.6 Approval required: Work shall not be done beyond the point indicated in each  
successive inspection without first obtaining the approval of the building official. The  
building official on notification shall make the requested inspections and shall either  
indicate the portion of the construction that is satisfactory as completed, or shall notify  
the permit holder or agent of the permit holder where a portion of the construction fails  
to comply with the code. The notification shall include specific reference to the code  
chapter and section numbers in violation in writing. Any portions that no do not comply  
shall be corrected and such portion shall not be covered or concealed until authorized by  
the building official. Neither the code official or the authority having jurisdiction are  
liable for expense entailed in the removal or replacement of material required to allow  
inspection.  
113.4 Violation penalties.  
(1) It is unlawful for any person, firm, or corporation to violate a provision of the code  
or fail to conform with the requirements thereof, or erect, construct, alter, extend, repair,  
move, remove, demolish, or occupy any building, structure, or equipment regulated by  
the code, or cause work to be performed or done in conflict with or in violation of the  
approved construction documents or directive of the enforcing agency or a permit or  
certificate issued under the code.  
(2) A violator shall be assessed a fine in accordance with the act and may be subject to a  
review that could result in licensing action pursuant to the skilled trades regulation act,  
2016 PA 407, MCL 339.5101 to 339.6133.  
History: 2002 AACS; 2008 AACS; 2024 AACS.  
R 408.30572 Rescinded.  
History: 2002 AACS; 2008 AACS; 2010 AACS; 2014 AACS; 2024 AACS.  
R 408.30573 Rescinded.  
History: 2002 AACS; 2008 AACS; 2010 AACS; 2014 AACS; 2024 AACS.  
R 408.30574 Rescinded.  
History: 2002 AACS; 2008 AACS; 2014 AACS; 2024 AACS.  
R 408.30575 Rescinded.  
History: 2002 AACS; 2008 AACS; 2014 AACS; 2016 AACS; 2024 AACS.  
Page 8  
R 408.30576 Rescinded.  
History: 2002 AACS; 2003 AACS; 2008 AACS; 2010 AACS; 2014 AACS; 2024 AACS.  
R 408.30577 Applicability.  
Rule 577. Sections 806.1 and 906.1 are added to the code and 1401.2 and 1401.2.5 of  
the code are amended as follows:  
806.1. General. A building, facility, or element that is altered shall comply with section  
410.  
906.1. General. A building, facility, or element that is altered shall comply with section  
410.  
1401.2. Applicability. Structures existing before November 6, 1974, in which there is  
work involving additions, alterations, or changes of occupancy shall be made to conform  
to the requirements of this chapter or the provisions of chapters 5 to13 of the code. The  
provisions in sections 1401.2.1 to 1401.2.5 shall apply to existing occupancies that will  
continue to be, or are proposed to be, in groups A, B, E, F, I-2, M, R, and S. This rule  
shall not apply to buildings with occupancies in group H or I-1, I-3, or I-4.  
1401.2.5. Accessibility requirements. All portions of the buildings proposed for change  
of occupancy shall conform to the accessibility provisions of section 410.  
History: 2002 AACS; 2003 AACS; 2008 AACS; 2010 AACS; 2014 AACS; 2016 AACS.  
Page 9  
;