through or adjacent to the car platform. The elevator is for the exclusive use of certain
designated operating and maintenance employees and is installed in a grain or feed mill or
a similar structure that is not accessible to the general public.
(g) "Inspection" means the official determination by a general inspector of the condition
of all parts of equipment on which the safe operation of an elevator depends.
(h) "Private residence elevator" means any elevating device installed in or at a private
residence or installed in a building as a means of access to a private residence within such
building, provided the elevator is installed so that it is not accessible to the general public
or to other occupants in the building. The use is restricted to the owner and the owner's
immediate family and nonpaying guests. All other elevating device installations must be
classified as commercial.
(i) "Special elevating device" includes another lifting or lowering apparatus that is
guided as provided in section 3 of the act, MCL 408.803.
(j) "Temporary inspection" means the inspection of a permanent elevator that is to be
used on a temporary basis.
(k) “Maintenance” means the process of routine examination, lubrication, cleaning, and
adjustment of parts components or subsystems, or both, to ensure performance pursuant to
these rules and the American Society of Mechanical Engineers (ASME) A17.1.
(2) Terms defined in the act have the same meanings when used in these rules.
History: 2003 AACS; 2005 AACS; 2014 AACS; 2023 AACS.
R 408.7003 Applicability of national standards.
Rule 3. The following standards are adopted by reference.
(a) The following standards are available from the American Society of Mechanical
Engineers (ASME), 22 Law Drive, Box 2900, Fairfield, New Jersey 07007-2900,
subdivision:
(i) ASME A17.1- 2016 safety code for elevators and escalators, except for sections,
1.2.1(b), 1.2.1(c), 2.5.1.5.3, 2.8.3.3.2, 2.8.6, 2.11.1.3, 2.11.1.4, 2.11.7.2, 2.11.7.2.1,
2.11.7.2.2, 2.11.7.2.3, 2.11.7.2.4, 2.11.7.2.5, 2.12.7.2.1(c), 2.12.7.2.2, 2.14.2.2(f), 2.14.2.6,
2.14.5.9.2, 2.22.2, 2.27.3.1.6(c), 3.18.3.8.3, 3.19.5.2, 3.22.1.6, 5.3.1.1.1, 5.3.1.1.2,
5.3.1.2.1, 5.3.1.14.3, 5.4.10.1, 5.4.10.2, 5.11, 5.12, 5.12.1, 5.12.1.1, 5.12.1.2, 5.12.1.3,
5.12.1.4, 5.12.2, 5.12.3, 8.6.1.7.1, 8.6.4.19.12 (b), 8.6.4.20.1(b), 8.6.4.20.1(b)(1),
8.6.4.20.1(b)(2), 8.6.4.20.3(a)(2), 8.6.4.20.3 (2)(b), 8.6.4.20.3 (g), 8.6.4.20.4 (b),
8.6.4.20.4 (b)(1), 8.6.4.20.4 (b)(2), 8.6.4.20.10(b), 8.6.4.20.10(b)(1), 8.6.4.20.10(b)(2),
8.6.5.8, 8.6.7.11 to 8.6.7.11.3, 8.6.7.12, 8.6.7.12.1, 8.6.7.12.2, 8.6.11.5 to 8.6.11.5.6,
8.6.11.10 to 8.6.11.10.4, 8.7.2.14.5.2, 8.10.1.1.3, 8.10.1.2, 8.11.1.1, 8.11.1.1.1, 8.11.1.1.2,
8.11.5.14 to 8.11.5.16. Cost $252.00.
(ii) ASME A17.2- 2017 guide for inspection of elevators, escalators, and moving walks.
Cost $195.00.
(iii) ASME A17.3-2017 safety code for existing elevators and escalators. Cost $168.00.
(iv) ASME A17.6- 2017 standard for elevator suspension, compensation, and governor
systems. Cost $92.00.
Page 2