(c) Abrasion, scrubbing, or peening causing loss of more than 1/3 of the original diameter
of the outside wires.
(d) Severe corrosion.
(e) Severe kinking, severe crushing, or other damage resulting in distortion of the rope
structure.
(f) Heat damage resulting from a torch or arc caused by contact with electrical wires.
(g) Reduction from normal diameter of more than 3/64 inch for diameters up to and
including 3/4 inch; 1/16 inch for diameters 7/8 inch to 1-1/8 inches; 3/32 inch for diameters
1-1/4 inches to 1-1/2 inches. Marked reduction in diameter indicates deterioration of the
core resulting in lack of proper support for the load-carrying strands. Excessive rope stretch
or elongation may be an indication of internal deterioration.
(h) Bird-caging or other distortion resulting in some members of the rope structure
carrying more load than others.
(i) Noticeable rusting or development of broken wires in the vicinity of attachments. If
this condition is localized in an operating rope, the section in question can be eliminated
by making a new attachment. This may be done rather than replacing the entire rope.
(2) Wire ropes used to support, suspend, bear, or control forces and weights involved in
the movement and utilization of tubs, cars, chairs, seats, gondolas, other carriers, the
sweeps or other supporting members of a ride or device shall not be lengthened or repaired
by splicing.
(3) Couplings, sockets, and fittings shall be of a design and type approved by the board
and installed in accordance with the instructions or specifications of the designer, engineer,
or manufacturer.
History: 1979 AC; 2003 AACS.
R 408.835 Wooden components.
Rule 35. Footings, splices, uprights, track timbers, ledgers, sills, laps, bracing, flooring,
and all other wooden components of rides, and structures shall be inspected for
deterioration, cracks, or fractures. Wooden members found to be defective shall be replaced
with material of equal or greater strength and capacity. Repairs and replacements to fixed
roller coasters shall be made in accordance with the recommendations of the manufacturer.
History: 1979 AC; 1983 AACS.
R 408.837 Ride location.
Rule 37. (1) A ride shall be placed on solid footings and shall be secured to prevent
shifting, tipping, swaying, or erratic motion. The provision pertinent to erratic motion or
sway does not apply to a ride designed to permit flotation characteristics or flexibility.
Use of shim blocks shall be kept to a minimum. Depressions in the ground near the ride
footings shall be filled and tamped and adequate means of drainage shall be provided to
prevent water from collecting and softening supporting areas. The area surrounding the
ride shall be clear and shall be kept free from trash and tripping hazards.
(2) A fixed ride permanently erected in an amusement park shall be set on properly
designed and constructed foundations or footings and shall be secured to these footings in
Page 8